Research Article

Occupancy Inference from Aggregate Smart-Meter Data Across Sampling Resolutions: A Controlled Synthetic Privacy Study

Authors

  • Zeinab Parandavar * Department of Computer Engineering, Rasht Branch, Islamic Azad University, Rasht, Iran.
  • Arman Daliri Department of Computer Engineering, Karaj Branch, Islamic Azad University, Karaj, Iran.

https://doi.org/10.48314/ceti.v3i3.95

Abstract

Fine-grained smart-meter records support legitimate energy services while also enabling behavioral inference. This study isolates one controllable disclosure parameter—the reporting interval—and examines how it changes retrospective occupancy inference in a controlled synthetic benchmark. Sixty households are simulated for 14 days at one-second native resolution, then mean-aggregated to 1-second, 1-minute, 5-minute, and 15-minute releases. Non-overlapping 30-minute windows are represented by statistical and temporal features and evaluated with logistic regression, random forest, gradient boosting, and a two-state Gaussian Hidden Markov Model (HMM). The primary protocol trains on 42 households and evaluates 18 previously unseen households (12,096 windows); uncertainty is summarized by a 500-draw household-cluster bootstrap. Random forest attains its highest pooled Receiver Operating Characteristic – Area Under the Curve (ROC AUC) at 1 minute (0.794; 95% bootstrap interval 0.768–0.817) and declines to 0.724 (0.703–0.747) at 15 minutes. Gradient boosting reaches 0.734 (0.708–0.761) at 15 minutes. Statistical-only feature sets consistently outperform temporal-only sets, showing that coarse releases can retain occupancy-linked level information after short transitions are suppressed. The HMM remains at AUC 0.722 at every resolution because it receives only the 30-minute mean, which is invariant under the nested averaging scheme. The analysis also exposes three interpretive boundaries: The midpoint label is estimated using the complete window and is therefore retrospective; a secondary time split changes several design factors and cannot identify the causal value of household-specific history; and the AUC 0.650 line is an analytical benchmark rather than a legal or operational privacy threshold. The findings support data minimization as a useful but incomplete control: 15-minute averaging reduces some model performance without eliminating inferential exposure in this generator. External validation on occupancy-labeled homes, prospective inference, and release of code, generated traces, predictions, and bootstrap draws are required before deployment claims. 

Keywords

Smart meter Occupancy inference Data granularity Privacy exposure Synthetic simulation Household-cluster bootstrap
References (30)
  1. [1] Hart, G. W. (1992). Nonintrusive appliance load monitoring. Proceedings of the IEEE (pp. 1870–1891). IEEE. https://doi.org/10.1109/5.192069

  2. [2] Molina-Markham, A., Shenoy, P., Fu, K., Cecchet, E., & Irwin, D. (2010). Private memoirs of a smart meters. Proceedings of the 2nd ACM workshop on embedded sensing systems for energy-efficiency in building (pp. 61–66). Association for Computing Machinery (ACM). https://doi.org/10.1145/1878431.1878446

  3. [3] Lisovich, M. A., Mulligan, D. K., & Wicker, S. B. (2010). Inferring personal information from demand-response systems. IEEE Security & Privacy, 8(1), 11–20. https://doi.org/10.1109/MSP.2010.40

  4. [4] McKenna, E., Richardson, I., & Thomson, M. (2012). Smart meter data: Balancing consumer privacy concerns with legitimate applications. Energy Policy, 41, 807–814. https://doi.org/10.1016/j.enpol.2011.11.049

  5. [5] Beckel, C., Sadamori, L., Staake, T., & Santini, S. (2014). Revealing household characteristics from smart meter data. Energy, 78, 397–410. https://doi.org/10.1016/j.energy.2014.10.025

Article Metrics

How to Cite

Parandavar, Z., & Daliri, A. (2026). Occupancy Inference from Aggregate Smart-Meter Data Across Sampling Resolutions: A Controlled Synthetic Privacy Study. Computational Engineering and Technology Innovations, 3(3), 249-264. https://doi.org/10.48314/ceti.v3i3.95

Similar Articles