Exact Predictive Ventilation Control with Causal Occupancy Forecasts and Concentration Guarantees

Authors

  • Omar Mar Cornelio * Centro de Estudio de Matematica Computacional, Universidad de las Ciencias Inform aticas, La Habana, Cuba.
  • Mingyue Wang School of computer and information, Lanzhou University of Technology, China.
  • Rania A. Mahmoud Department of Computer Science, Alexandria University, Alexandria, Egypt.

https://doi.org/10.48314/ceti.v3i2.83

Abstract

Predictive ventilation depends on both the mathematical plant and the information available when an airflow command is selected. We study these dependencies in a fully specified, single-zone apartment benchmark. For a well-mixed carbon dioxide balance with nonnegative generation and piecewise constant airflow, we derive an exact propagation map and prove that predicted concentration is jointly convex in the planned airflow sequence after the state variables are eliminated. The resulting finite-horizon problem retains the cubic fan law without successive linearization. A monotone one-step filter then enforces a selected concentration bound under declared occupancy and plant-parameter envelopes. We evaluate seven controllers on twelve independent, paired week-long simulations, using eight separate training weeks for occupancy-model estimation and reactive-controller tuning. Filtered Model Predictive Control (MPC) consumes 26.386 kWh/week of modeled fan-plus-heating energy, compared with 27.726 for the tuned rule and 28.965 for the original 1000/850 ppm rule. Its paired difference from the tuned rule is −1.340 kWh/week, with a pointwise 95% interval of [−1.465, −1.214]. A causal conditional-mean forecast with a five-minute occupancy-report delay yields only 0.045 occupants of one-step Mean Absolute Error (MAE), yet its unfiltered controller spends 44.175 minutes per occupied person-hour above 1000 ppm, predominantly through small exceedances. The filter removes these exceedances in the matched model at an added 0.037 kWh/week. Four paired mismatch tests show why the guarantee must use valid parameter envelopes. The results establish a reproducible separation between forecast quality, energy performance, and conditional concentration invariance; they do not constitute residential field validation or a general indoor-air-quality guarantee.        

Keywords

Demand-controlled ventilation Exact discretization Convex optimization Causal occupancy forecasting Model predictive control Concentration invariance
References (31)
  1. [1] Fisk, W. J., & De Almeida, A. T. (1998). Sensor-based demand-controlled ventilation: A review. Energy and Buildings, 29(1), 35–45. https://doi.org/10.1016/s0378-7788(98)00029-2.

  2. [2] Persily, A., Bahnfleth, W. P., Kipen, H., Lau, J., Mandin, C., Sekhar, C., ..., & Weekes, L. C. N. (2022). ASHRAE position document on indoor carbon dioxide. ASHRAE, 64, 50-52. https://www.ashrae.org/file%20library/about/position%20documents/pd-on-indoor-carbon-dioxide-english.pdf

  3. [3] Persily, A., & de Jonge, L. (2017). Carbon dioxide generation rates for building occupants. Indoor Air, 27(5), 868–879. https://doi.org/10.1111/ina.12383.

  4. [4] Mayne, D. Q., Rawlings, J. B., Rao, C. V, & Scokaert, P. O. M. (2000). Constrained model predictive control: Stability and optimality. Automatica, 36(6), 789–814. https://doi.org/10.1016/s0005-1098(99)00214-9

  5. [5] Oldewurtel, F., Parisio, A., Jones, C. N., Gyalistras, D., Gwerder, M., Stauch, V., …, & Morari, M. (2012). Use of model predictive control and weather forecasts for energy efficient building climate control. Energy and Buildings, 45, 15–27. https://doi.org/10.1016/j.enbuild.2011.09.022

Article Metrics

How to Cite

Cornelio, O. M., Wang, M., & Mahmoud, R. A. (2026). Exact Predictive Ventilation Control with Causal Occupancy Forecasts and Concentration Guarantees. Computational Engineering and Technology Innovations, 3(2), 68-88. https://doi.org/10.48314/ceti.v3i2.83

Similar Articles

1-10 of 45

You may also start an advanced similarity search for this article.